Filters
Question type

Study Flashcards

Pneumatic pumps have limited passageways and can become fouled by solid objects, so rotating pumps are a practical solution.

A) True
B) False

Correct Answer

verifed

verified

If a sewage pump or ejector serves a single-family dwelling, it must be capable of passing a solid at least 1½ inches in diameter and have a ____ minimum discharge pipe size.


A) 1½-inch
B) 2-inch
C) 3-inch
D) 4-inch

E) A) and B)
F) None of the above

Correct Answer

verifed

verified

B

Which of the following is NOT a factor in the selection of a pump?


A) volume of material to be displaced
B) height the material must be lifted
C) average rate of rainfall
D) power supply available

E) None of the above
F) A) and D)

Correct Answer

verifed

verified

The three model codes require that sewage pumps and ejectors have alarms that are audible, visual, or a combination of both for the high-level limit.

A) True
B) False

Correct Answer

verifed

verified

If a sewage pump or ejector serves a commercial building, it must be capable of passing a 2-inch diameter solid and have a _____ minimum discharge pipe size.


A) 2-inch
B) 3-inch
C) 4-inch
D) 6-inch

E) A) and B)
F) A) and C)

Correct Answer

verifed

verified

Full-ported check valves installed in sewage systems to prevent backflow are called __________.


A) RPZs
B) atmospheric-type vacuum breakers
C) double-check valve assemblies
D) backwater valves

E) C) and D)
F) A) and D)

Correct Answer

verifed

verified

D

Sewage pumping stations are not prone to blockages and require little maintenance.

A) True
B) False

Correct Answer

verifed

verified

If a sewage pump or ejector receives discharge from either a water closet or urinal, it must have a minimum capacity of ____ gallons per minute.


A) 10
B) 15
C) 20
D) 25

E) B) and C)
F) A) and B)

Correct Answer

verifed

verified

In which type of basin are the pump and fluid sensors are submerged in the waste?


A) dry
B) wet
C) septic
D) cistern

E) A) and C)
F) B) and D)

Correct Answer

verifed

verified

B

_______ are installed as close to the pump as possible so that components can be easily removed from the system.


A) Caps
B) Tees
C) Elbows
D) Unions

E) A) and B)
F) B) and D)

Correct Answer

verifed

verified

The vent for a pneumatic ejector must be vented separately to the outdoors.

A) True
B) False

Correct Answer